Experimental characterization of compact fluorescent lamps for harmonic analysis of power distribution systems

The modeling of a compact fluorescent lamp for harmonic analysis under terminal voltage variation is presented in this paper. The compact fluorescent lamp is represented with the diode bridge rectifier model, which is commonly used for harmonic analysis. The set of parameters is estimated for differ...

Mô tả đầy đủ

Đã lưu trong:
Chi tiết thư mục
Tác giả chính: Andrés C. Henao-Muñoz (Universidad Nacional de Colombia), Javier G. Herrera-Murcia (Universidad Nacional de Colombia), Andrés J. Saavedra-Montes (Universidad Nacional de Colombia)
Định dạng: Other
Ngôn ngữ:en_US
Năm xuất bản: Instituto Tecnológico Metropolitano 2018
Chủ đề:
Truy cập Trực tuyến:http://lrc.quangbinhuni.edu.vn:8181/dspace/handle/DHQB_123456789/3847
Tags: Thêm thẻ
Không có thẻ, Hãy là người đầu tiên gắn thẻ bản ghi này!
id oai:localhost:DHQB_123456789-3847
recordtype dspace
spelling oai:localhost:DHQB_123456789-38472018-10-22T08:44:21Z Experimental characterization of compact fluorescent lamps for harmonic analysis of power distribution systems Tecno Lógicas Andrés C. Henao-Muñoz (Universidad Nacional de Colombia) Javier G. Herrera-Murcia (Universidad Nacional de Colombia) Andrés J. Saavedra-Montes (Universidad Nacional de Colombia) Technology Engineering (General) Civil engineering (General) The modeling of a compact fluorescent lamp for harmonic analysis under terminal voltage variation is presented in this paper. The compact fluorescent lamp is represented with the diode bridge rectifier model, which is commonly used for harmonic analysis. The set of parameters is estimated for different values of the terminal voltage applied to the lamp. The equations to estimate the parameters and the required measurements to calculate them are presented. To characterize the lamp an experiment is carried out varying the RMS terminal voltage from 10 V to 131.6 V and for each terminal voltage value the apparent, real and reactive powers, the power factor, the current and the applied voltage are registered. To validate the model in the range of the terminal voltage, the total harmonic distortion of current calculated with the experimental signal and the total harmonic distortion of current calculated with simulation software are compared. The results show that the compact fluorescent lamp can be represented for one set of parameters in the operation range of the terminal voltage suggested by the manufacture. 2018-08-23T08:05:51Z 2018-08-23T08:05:51Z 2018 Other http://lrc.quangbinhuni.edu.vn:8181/dspace/handle/DHQB_123456789/3847 en_US Instituto Tecnológico Metropolitano
institution Trung tâm Học liệu Đại học Quảng Bình (Dspace)
collection Trung tâm Học liệu Đại học Quảng Bình (Dspace)
language en_US
topic Technology
Engineering (General)
Civil engineering (General)
spellingShingle Technology
Engineering (General)
Civil engineering (General)
Andrés C. Henao-Muñoz (Universidad Nacional de Colombia)
Javier G. Herrera-Murcia (Universidad Nacional de Colombia)
Andrés J. Saavedra-Montes (Universidad Nacional de Colombia)
Experimental characterization of compact fluorescent lamps for harmonic analysis of power distribution systems
description The modeling of a compact fluorescent lamp for harmonic analysis under terminal voltage variation is presented in this paper. The compact fluorescent lamp is represented with the diode bridge rectifier model, which is commonly used for harmonic analysis. The set of parameters is estimated for different values of the terminal voltage applied to the lamp. The equations to estimate the parameters and the required measurements to calculate them are presented. To characterize the lamp an experiment is carried out varying the RMS terminal voltage from 10 V to 131.6 V and for each terminal voltage value the apparent, real and reactive powers, the power factor, the current and the applied voltage are registered. To validate the model in the range of the terminal voltage, the total harmonic distortion of current calculated with the experimental signal and the total harmonic distortion of current calculated with simulation software are compared. The results show that the compact fluorescent lamp can be represented for one set of parameters in the operation range of the terminal voltage suggested by the manufacture.
format Other
author Andrés C. Henao-Muñoz (Universidad Nacional de Colombia)
Javier G. Herrera-Murcia (Universidad Nacional de Colombia)
Andrés J. Saavedra-Montes (Universidad Nacional de Colombia)
author_facet Andrés C. Henao-Muñoz (Universidad Nacional de Colombia)
Javier G. Herrera-Murcia (Universidad Nacional de Colombia)
Andrés J. Saavedra-Montes (Universidad Nacional de Colombia)
author_sort Andrés C. Henao-Muñoz (Universidad Nacional de Colombia)
title Experimental characterization of compact fluorescent lamps for harmonic analysis of power distribution systems
title_short Experimental characterization of compact fluorescent lamps for harmonic analysis of power distribution systems
title_full Experimental characterization of compact fluorescent lamps for harmonic analysis of power distribution systems
title_fullStr Experimental characterization of compact fluorescent lamps for harmonic analysis of power distribution systems
title_full_unstemmed Experimental characterization of compact fluorescent lamps for harmonic analysis of power distribution systems
title_sort experimental characterization of compact fluorescent lamps for harmonic analysis of power distribution systems
publisher Instituto Tecnológico Metropolitano
publishDate 2018
url http://lrc.quangbinhuni.edu.vn:8181/dspace/handle/DHQB_123456789/3847
_version_ 1717292450773467136
score 9,463379